Advancing Care Through Reliable Engineering
DYNAMIC PRODUCT INSIGHTS

Dynamic Product Specifications​

DIN Standard Medical Gas Terminal Unit (German Standard)

  • Reference Standards ISO 9170-1, YY 0801.1, DIN 13260

  • Functions and Performance Parameters

  1. Applicable Gases: Oxygen ($O_2$), Vacuum (VAC), Medical Air (AIR), Nitrous Oxide ($N_2O$), Carbon Dioxide ($CO_2$), Instrument Air (IAIR), Driving Nitrogen ($N_2$).

  2. Maximum Flow Rate: a) $> 200\text{ L/min}$ at a nominal pressure of $400\sim500\text{ kPa}$ ($O_2$, AIR, $N_2O$, $CO_2$) b) $> 350\text{ L/min}$ at a nominal pressure of $700\sim1000\text{ kPa}$ (IAIR, $N_2$) c) $> 25\text{ L/min}$ for Vacuum (VAC)

  3. Maximum Withstand Pressure: $3\text{ MPa}$.

  4. Plug-in/Unplug Cycle Life: $150,000\text{ cycles}$.

  5. Service Life: $10\text{ years}$.

  6. Inlet Connection Types: Copper pipe, flexible hose, threaded connection (M14, NIST, DISS), etc.

  7. Equipped with a release/ejection protection mechanism to prevent accidental injury caused by probe pop-out.

  8. Gas-specific pin-indexing (poka-yoke) design for the front and rear bodies to prevent hazards caused by gas cross-connection.

BS Standard Medical Gas Terminal Unit (British Standard) I. Reference Standards ISO 9170-1, YY 0801.1, BS 5682

  • Functions and Performance Parameters

  1. Applicable Gases: Oxygen ($O_2$), Vacuum (VAC), Medical Air (AIR), Nitrous Oxide ($N_2O$), Carbon Dioxide ($CO_2$), Instrument Air (IAIR), Driving Nitrogen ($N_2$).

  2. Maximum Flow Rate: a) $> 200\text{ L/min}$ at a nominal pressure of $400\sim500\text{ kPa}$ ($O_2$, AIR, $N_2O$, $CO_2$) b) $> 350\text{ L/min}$ at a nominal pressure of $700\sim1000\text{ kPa}$ (IAIR, $N_2$) c) $> 25\text{ L/min}$ for Vacuum (VAC)

  3. Maximum Withstand Pressure: $3\text{ MPa}$.

  4. Plug-in/Unplug Cycle Life: $150,000\text{ cycles}$.

  5. Service Life: $10\text{ years}$.

  6. Inlet Connection Types: Copper pipe, flexible hose, threaded connection (M14, NIST, DISS), etc.

  7. Gas-specific pin-indexing (poka-yoke) design for the front and rear bodies to prevent hazards caused by gas cross-connection.

JIS Standard Medical Gas Terminal Unit (Japanese Standard) I. Reference Standard JIS T 7101

  • Functions and Performance Parameters

  1. Applicable Gases: Oxygen ($O_2$), Vacuum (VAC), Medical Air (AIR), Nitrous Oxide ($N_2O$), Carbon Dioxide ($CO_2$).

  2. Maximum Flow Rate: a) $> 200\text{ L/min}$ at a nominal pressure of $400\sim500\text{ kPa}$ ($O_2$, AIR, $N_2O$, $CO_2$) b) $> 40\text{ L/min}$ for Vacuum (VAC)

  3. Maximum Withstand Pressure: $3\text{ MPa}$.

  4. Plug-in/Unplug Cycle Life: $150,000\text{ cycles}$.

  5. Service Life: $10\text{ years}$.

  6. Inlet Connection Types: Copper pipe, flexible hose, threaded connection (M14, NIST, DISS), etc.

  7. Gas-specific pin-indexing (poka-yoke) design for the front and rear bodies to prevent hazards caused by gas cross-connection.

JIS gas outlet

BS gas outlet

DIN gas outlet

Dynamic Product Specifications

Dynamic Multi-Phase Waveform Technology
Our proprietary biphasic dynamic system customizes the pulse structure, modifying energy flow automatically in response to dynamic physiological resistance.
Integrate medical logs securely into the central hospital network via fully encrypted cellular and high-throughput Wi-Fi, fully adhering to national standard regulations.
Monitors changes in biological impedance and changes treatment metrics mid-pulse, guaranteeing optimal efficacy for varying patient physiological builds.

Consultation and negotiation

Quality & Certifications
0 +
R&D and Technology
0 +
Warehouse & Logistics
0 +
Global Markets
0 +